Analog Input 1 Range
0–9 V
Biasing Current Range
10–300 mA adjustable
Card Dimensions
100×160 mm (Euro-card DIN 41494)
Clock Frequency
100/200 Hz (±10%) selectable
Connection Type
32-pin male connector, DIN 41612 form D
Current Consumption
<1 A
Differential Input Range
0–10 V, Rin 100 kΩ
Fuse Rating
2.5 A, slow-blow
Operating Voltage
24 VDC (+40%/–5%), 22–35 V range
Output Current Measurement
0–800 mA (1 mV/mA)
Panel Height
3 HE (128.4 mm)
Panel Width
3 TE (component), 1 TE (solder)
Permissible Operating Temperature
0–50 °C
Power Consumption
<25 VA
Ramp Time Adjustment
30 ms to 1 s or 5 s selectable
Storage Temperature
-25–85 °C
Weight
0.1 kg