Command Output Level
0-6 V across test point BU1
Input Control Voltage
± 9 V
Input Signal Range
±10 V
Maximum Output Current
800 mA
Maximum Output Load
R 19.5 Ω
Minimum Input Load
≥ 500 Ω
Minimum Output (bias) Current
20 mA
Overload Protection
Integrated short-circuit and thermal overload protection
Power Requirements
30 W
Power Supply Voltage
24 VDC ±10%
Pulse Frequency
160 to 180 Hz
Space Requirements
1 div. = 5.08 mm; Face plate requirement: 8 divisions
Temperature Drift
0.5% (from Imax)/K
Test Points
BU2 and BU3 (measurement scale: 1 mV = 1 mA)
Weight
0.33 lb (0.15 kg)