The Bosch Rexroth Indramat VT 3017 S37 from the VT 3000 Analog Amplifiers series combines exceptional precision and reliability in a compact 0.15 kg (0.33 lb) housing. Powered by a 24 VDC ±10% power supply voltage and consuming 30 W under full load, this amplifier maintains stable performance with an input control voltage of ±9 V and exhibits a temperature drift of 0.5%/K (from Imax). Designed for demanding industrial environments, the unit operates continuously within a pulse frequency range of 160–180 Hz to ensure rapid and accurate solenoid control. Robust construction and streamlined electronics deliver consistent performance with minimal maintenance.



Featuring dual solenoid outputs, the VT 3017 S37 provides BU2 (Solenoid B) and BU3 (Solenoid A) output currents of 20–800 mA and a maximum output current of 800 mA. It drives coils with up to 19.5 Ω maximum output load while requiring a minimum input load of ≥500 Ω and a minimum output bias current of 20 mA for stable operation. Compliance with EMC Directive 2014/30/EU guarantees immunity to unwanted emissions, and certified performance up to an operational altitude of ≤2000 m makes it suitable for high-altitude installations. Front-panel LED status indicators provide real-time feedback on power, normal operation, and error conditions, simplifying system monitoring and troubleshooting.



Measuring 185 mm (7.28 in) width and weighing only 0.15 kg, the VT 3017 S37 supports dense cabinet layouts and flexible mounting options. Its rugged design and compliance with industrial standards ensure seamless integration into automation architectures, making it an ideal choice for precise solenoid actuation in demanding manufacturing processes.

Technical Specifications

BU2 (Solenoid B) Output Current
20–800 mA

BU3 (Solenoid A) Output Current
20–800 mA

EMC Compliance
Meets EMC Directive 2014/30/EU

Input Control Voltage
±9 V

Maximum Output Current
800 mA

Maximum Output Load
19.5 Ω

Minimum Input Load
≥500 Ω

Minimum Output Bias Current
20 mA

Operational Altitude
≤2000 m above sea level

Power Consumption
30 W

Power Supply Voltage
24 VDC ±10%

Pulse Frequency
160–180 Hz

Status Indicators
LEDs for power, status and error

Temperature Drift
0.5%/K (from Imax)

Weight
0.15 kg (0.33 lb)

Width
185 mm (7.28 in)

Shipping & Payment Options
DHL-logo FexEd-logo UPS-logo freight-icon

AmEx-icon Mastercard-icon Visa-icon wire-transfer-icon
Warranty
1-year-warranty
Indramat USA 1 Year Warranty
Repair
product repair We offer a repair service for the VT 3017 S37.
Exchange
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo