VT 3000-3X-ES43A8-2590
VT 3000 Analog Amplifiers
With a nominal operating voltage of 24 Volts DC and a range from 22 to 39 Volts DC, the amplifier's power consumption does not exceed 50 VA and similarly, the current consumption does not go beyond 1 Amp. It includes a protective 2.5 Amp fuse and to mitigate damage, it must only be plugged in or removed when switched off. Usage of plugs with LED displays or free wheel diodes is not advised. It is crucial to keep aerial lines and RF sources at least a meter away from the amplifier and refrain from placing solenoid or signal lines near power lines. The amplifier should be measured using equipment with an input impedance greater than 100 kiloohms.
Technical Specifications
Connection
32-pin terminal strip
Compliance
DIN 41612
Dimensions
100 x 160 mm
Format
Euro card
Ambient Temperature
0 to 50 degrees Celsius
Storage Temperature
-25 to 85 degrees Celsius
Protection Needed From
Dust, moisture, corrosive elements
Weight
0.13 kg
Height
128.4 mm
Front Plate Width
5.08 mm
Operating Voltage
24 Volts DC
Voltage Range
22 to 39 Volts DC
Power Consumption
50 VA max
Current Consumption
1 Amp max
Fuse
2.5 Amps
Power State for Plugging/Unplugging
Switched off
LED displays or Free Wheel Diodes Usage
Not recommended
Measuring Equipment Impedance
Greater than 100 kiloohms
Proximity to RF Sources
At least 1 meter
Solenoid or Signal Lines
Avoid laying near power lines.