Coil Resistance R20
2.5 Ω
Degree Of Protection
IP 65 as per DIN 40 050 and IEC 14 434/5
Duty Cycle
100%
Flow Direction
See symbol
Hysteresis
≤ 0.3%
Max. Permitted Viscosity
60…3700 SUS (10…800 cSt)
Max. Working Pressure Port P
4570 PSI (315 bar)
Max. Working Pressure Port T
≤ 29 PSI (2 bar)
Nominal Flow At ∆p = 116 Psi
21 GPM (80 l/min)
Position Transducer Connector
Special Connector
Power Consumption Max
50 W
Pressure Medium Temperature
-4°…176°F (-20°…+80°C)
Response Time 100% Signal Change
25 ms
Solenoid Current Max
3.7 A
Viscosity, Recommended
100…465 SUS (20…100 cSt)