Controller Logic
Pressure switch comparison for valve and pressure
Feedback Detection
Cable break detection for position and pressure
Housing Type
Snap-in with plug-in screw connectors
LED Indication
Readiness, enable and cable-break LEDs
Max Cable Length
Up to 50 m
Measuring Point Selection
Switchable test jack for multiple ranges
Module Type
Analog amplifier module
Operating Temperature
Meets specified environmental temperature ranges
Operating Voltage
DC/DC input with reverse-polarity protection
Pressure Command Input
0–10 V configurable; switchable to 4–20 mA
Pressure Switch Output
Two 24 V outputs with adjustable thresholds
Ramp Times
Adjustable for pressure command
Short-Circuit Protection
Inputs and outputs auto-cutoff on faults
System Circuits
Generates voltages for logic, output and signal processing