Type
Amplifier
Designed For
Controlled proportional pressure valves
Device Type
Analog
Solenoid Count
1
Connector Type
32-pole male multipoint
Weight
0.1 kilograms
Working Temperature
0 to 50 degrees Celsius
Storage Temperature
-25 to 85 degrees Celsius
Nominal Operating Voltage
24 Volts DC
Lower Limit Operating Voltage
22 Volts DC
Upper Limit Operating Voltage
35 Volts DC
Maximum Power Consumption
50 VA
Peak Current Consumption
1.8 Amps
Fuse Type
2.5 Amps slow-blow
Mounting Orientation
Vertical
Height
128.4 millimeters
Width
20 millimeters
Depth
165 millimeters
DIL Switches
Customizable
Ramp Time (Default Setting)
5 seconds
Pilot Current (Default Setting)
100 milliamps
Output Current (Default Setting)
800 milliamps
Clock Frequency (Default Setting)
200 Hertz
Assembly Requirement
Device must be de-energized
Relay Requirement
Conductors need gold-plates contacts
Solenoid Shielding
Required
Required Distance from Aerial Lines, Radar Systems, Radios
At least 1 meter
Laying Solenoid Conductors and Signal Lines near Power Lines
Not Recommended
Handling Requirement
Trained personnel only