Type
Analog Amplifier
Actuating Element
Solenoid
Controlled Valves
Direct and Pilot Operated
Position Feedback Support
No
Reverse Polarity Protection
Yes
Cable Break Protection
Yes, for current input between 4 and 20 milliamps
Short-Circuit Protection
Yes, of the solenoid conductor
Cable Break Detection
Yes, of the solenoid conductor
Ramp Generator
Yes, adjustable downwards and upwards direction
Differential Input
Yes, switchable from voltage to current input
Default Ramp Time
5 seconds
Default Pilot Current
100 milliamps
Default Peak Output Current
80 milliamps
Default Clock Frequency
200 Hertz
Nominal Operating Voltage
24 Volts DC
Operating Voltage Upper Limit
+35 Volts DC
Operating Voltage Lower Limit
+22 Volts DC
Peak Power Consumption
50 VA
Maximum Current Consumption
1.8 Amps
Ramp Time Range
30 milliseconds to 1 second or 5 second
External Interface Connector
32-pole male connector
Operating Temperature
0 to 50 degrees Celsius
Storage Temperature
-25 to +85 degrees Celsius
Weight
0.1 kilograms
Front Plate Dimensions
128.4 x 20 millimeters
Unit Depth
165 millimeters
Assembly Requirement
Only when de-energized.