The VT-VSPA2-50-1X-T5 is an efficient valve amplifier, equipped with five adjustable ramp times and internal limiters or attenuators. These utility limiters operate when paired with external command value potentiometers. The device boasts a power consumption less than 30VA and utilizes a Form D 32-pin male connector, in alignment with DIN 41612 regulations. A unique feature of this amplifier is its short ramp time, enabled during less than 100% command value step change. Ensuring the connection or disconnection to the input's two signal cables when applying or removing the command value voltage is crucial.
Furthermore, the amplifier offers an automatic de-energization of its output stages and resets to readiness upon any fault detection. Its output stages have a low enabled input voltage rating of 6.5V, and the outputs yield 1.5A solenoid current with 5 Ohms resistance. Additionally, the outputs maintain a clock pulse frequency just under 220Hz. Weighing a mere 0.13kg, the amplifier is designed for long-term storage in conditions between -25°C and 85°C. Notably, the device requires shielded solenoid cables and observes a minimum of 1m distance from any radio source. It is available for international shipping, backed up with a one-year support duration.

Technical Specifications

Adjustable Ramp Times
5

Ramp Time Input Command Value
Less than 100% command value step change

Power Consumption
Less than 30VA

Connector Type
Form D 32-pin male

Connector Compliance
DIN 41612 specs

Enabled Input Voltage Rating (inactive stage)
Not exceeding 6.5V

Solenoid Current
1.5A

Resistance at Output Stage
5 Ohms

Clock Pulse Frequency
Less than 220Hz with +/-10% tolerance

Weight
0.13kg

Storage Temperature
Between -25°C and 85°C

Solenoid Cable Type
Shielded

Command Value Cables Shielding
On one side

Radio Source Distance
Minimum of 1m

Cable Type for Solenoids
LiYCY cables (if less than or equal to 50m long)

Cable Cross-section
1.5mm2

Switching Modality
Using relays with gold-plated contacts

Shipping & Payment Options
DHL-logo FexEd-logo UPS-logo freight-icon

AmEx-icon Mastercard-icon Visa-icon wire-transfer-icon
Warranty
1-year-warranty
Indramat USA 1 Year Warranty
Repair
We offer a repair service for the VT-VSPA2-50-1X-T5.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo