The Bosch Rexroth Indramat CSH01.1C-SE-ENS-EN2-MEM-L1-S-RP-FW controller from the CSH Advanced Controllers series delivers precise single-axis drive control with a SERCOS Interface master communication module and a minimum SERCOS cycle time of 250 µs. It features two analog outputs, 7.5 W power consumption, and an inrush current of 4 A in the control section. Installation requires certified technicians under specified environmental conditions. Control section dimensions measure 103 mm x 49.5 mm x 241 mm and safety is ensured by the Starting Lockout (L1) option. The device supports 7 to 11 digital inputs and up to 4 digital outputs, plus one analog input and one relay contact. Encoder options include an IndraDyn/hiperface encoder, an EnDat2.1 encoder or encoder emulator, while firmware safety features are available separately.
Control Panel
Standard
Master Communication
SERCOS Interface
Max. Pulse Width
100 ms
Maximum Mouting Height
1000 MSL
No. of Digital Inputs
7 to 11
No. of Digital Outputs
0 - 4
Option 1 Encoder
IndraDyn/hiperface/1Vpp/TTL
Option 2 Encoder
EnDat 2.1/1 VPP/TTL
Power Consumption
7.5 W
Safety Option
Starting Lockout