Product Category: Electric Drives and Control Systems
RS232 Serial Port: Yes
SERCOS Cycle Duration: 250 microseconds
Digital Outputs: 5
Current Control Range: 62.5 to 125 microseconds
Position Control Range: 250 to 500 microseconds
X4 Slot Occupied By: Multi-Encoder interface
X8 Slot Occupied By: CANopen interface
Firmware: Provided separately
Digital Outputs Calibration Requirement: Yes
Analog Input Calibration Requirement: Yes
PWM Frequency Range: 2 to 16 kHz adjustable in 2 kHz increments
Communication Module: 1 W SERCOS 3 interface master
Safety Feature: S4 safety feature
Submerged Operation Suitability: No
Extreme Temperature Fluctuations Suitability: No
High Maximum Temperatures Suitability: No