The R911291197 (PPC-R02.2N-N-T2-B2-NN-FW) is a Bosch Rexroth Indramat controller designed for PLC or NC control applications. This unit is installed in conjunction with RECO02 modules and RMB02.2-04 type module carriers. DIP switches configure the unit for RECO bus operation from slot 0, with the RMB02.2-02 dual carrier available for applications not requiring the RECO bus. The device features an Ethernet 10 Mb interface (ETH01) and an Interbus fieldbus slave interface (IBS03). It is housed in a RECO unit enclosure, weighs 1.3kg, and requires a 6mm² grounding cable to the machine's central grounding point. Power requirements are 19.2–30 VDC (including ripple), rated at 24 VDC, with a tolerance of -15% to +20% as per EN61131-2:1994. Protection level is IP 20.

Technical Specifications

Product
Bosch Rexroth Indramat PPC-R Units

RMB02.2-04 type Module Carriers Installation
Yes

PPC-R unit control for RECO bus
Yes, in slot 0

DIP switches on RMB02.2-04
Need for configuration

RMB02.2-02 dual carrier use
Only if PPC-R is to be used without RECO bus

Power requirement while inserting or removing from module carriers
Power must be switched off

Grounding cable needed for controller-
Yes, 6mm²

Grounding for other devices and power supply
Star-shaped configuration

Protected
Yes, as per IP20 protection category

Weight of controller
1.3 Kg

Housing Version
Yes, for RECO unit

What is the fieldbus interface of PPC-R02.2N-N-T2-B2-NN-FW?

The PPC-R02.2N-N-T2-B2-NN-FW has an Interbus fieldbus slave interface IBS03.

What is the Ethernet interface of PPC-R02.2N-N-T2-B2-NN-FW?

The PPC-R02.2N-N-T2-B2-NN-FW is equipped with an Ethernet 10 Mb interface ETH01.

What is the rated power supply of PPC-R02.2N-N-T2-B2-NN-FW?

The PPC-R02.2N-N-T2-B2-NN-FW uses 24 VDC.

What is the permissible voltage range of PPC-R02.2N-N-T2-B2-NN-FW?

The PPC-R02.2N-N-T2-B2-NN-FW operates within 19.2 … 30 VDC.

What is the tolerance of PPC-R02.2N-N-T2-B2-NN-FW?

The PPC-R02.2N-N-T2-B2-NN-FW has a tolerance of -15% to +20%.

PPC R02.2N-N-T2-B2-NN-FW

PPC-RO2.2N-N-T2-B2-NN-FW

PPC.R02.2N-N-T2-B2-NN-FW

PPCR02.2N-N-T2-B2-NN-FW

PPCR022NNT2B2NNFW

PPC R02 2N N T2 B2 NN FW

ppc-r02.2n-n-t2-b2-nn-fw

PPCR02.2NNT2B2NNFW

PPC R02.2N N T2 B2 NN FW

Internal Product Review

The PPC-R02.2N-N-T2-B2-NN-FW provides combined Interbus and Ethernet support, making it suitable for networked automation with varied field devices. Its solid construction ensures dependable industrial performance.