Or speak to a sales representative for additional information:
Type
Single-axis Control Unit
Digital Inputs
Three
Position Control Time
500 - 1000 µs
Current Control Time
125 µs
Velocity Control Time
250 - 500 µs
Switching Frequencies
8 kHz, 4 kHz, 2 kHz
Master Communication Interface
Sercos III
Supported Encoders
HiperFace, TLL, 1 Vpp, Indradyn
Power Consumption
8 W
Power Required
24 W DC
Inrush Current (Max Pulse Width of 100 ms)
4.5 A
Additional Interface
RS232 serial