Analog inputs: Three
Voltage rating: +/-10V
Current rating: 0mA - 20A
Input resolution: 13 bits
Interface: H1
Compatibility: HCS02, HCS03, HCS04 power sections
Operating requirement: Discharge through grounding mechanism
Grounding connection cross-section: At least 10mm2
Housing: Drive controller
Safety requirement: Functional emergency stop switch
Scope: Extended
Axis: One
Analog outputs: Two
Shipping: International
Velocity control cycle times: 125µs and 250µs
Analog current inputs bandwidth: 1.3kHz (-3dB)
Analog current inputs resistance: Maximum 300 Ohms
Output protection: Against overload and short circuit
Relay output: Type 2 at X33 connecting point
Relay time: Maximum 10ms pick up and drop out relays
Mechanical switching cycles: 1 x 108
Digital inputs and outputs standard: IEC 61131.