Use
                                Control and Monitor AC electrical motors                            
                                Interface
                                RS-232 serial interface                            
                                Status Display
                                H1 status display                            
                                Built-in Power Supply
                                Yes                            
                                Rated Current Requirement
                                200 A                            
                                Operating Supply Voltage
                                AC 3 × 400 – 480 V                            
                                Drive Configuration
                                4/8 kHz drive                            
                                Drive Power Voltage
                                0 – 380 V                            
                                System Frequency
                                800/1600 Hz                            
                                Drive Current Requirement
                                120/95 A                            
                                Continuous Power Delivery
                                47/37 kW                            
                                Plug-in Slots
                                5                            
                                Interface Slot U1
                                SERCOS                            
                                Feedback
                                Digital Servo and Resolver                            
                                Software
                                Firmware Module ESM 02.3                            
                                Housing Protection Category
                                IP 20                            
                                Maximum Operating Altitude
                                1000 m/sea level                            
                                Maximum Temperature
                                +55 degree Celsius with derating                            
The DKR02.1-W200N-BE32-01-FW drive controller from Bosch Rexroth Indramat accepts 3-phase 400–480 V input, and outputs 200 A via an integrated power module. It operates at 4 kHz or 8 kHz with built-in blower cooling. Its enclosure is rated IP20 and is designed for protected indoor environments with airflow.
            
            
            
        
            