Function Numeric Code: 43
Version Function Numeric Code: 02
Controller Voltage Input: 400 to 480 Volts AC
Controller Voltage Input Tolerance: ±10%
Controller Control Voltage: 230 Volts AC
Controller Control Voltage Tolerance: ±10%
Frequency Range: 50 to 60 Hertz
Control Circuit Power: 200 VA
Rated Continuous Current (4 kHz): 71 Amps
Rated Continuous Current (8 kHz): 60 Amps
Rated Controller Current: 71 Amps
Peak Power Rating (4 kHz): 26 kilowatts
Peak Power Rating (8 kHz): 22 kilowatts
Continuous Regenerated Power: 22 kilowatts
Max Regenerated Power: 26 kilowatts
Drive Controller Power Voltage: 0 to 380 Volts AC
Total Power Dissipation: 900W
Cooling: Built-in Blower
Command Communication: SERCOS Interface
Feedback: Digital Servo and Resolver
Bleeder: Included
Transportation: Shock-damped Supports Recommended
Storage Temperature Range: -30 to 85 degrees Celsius
Installation and Commissioning: Trained Personnel Only.