Operating Voltage: 3-phase AC 3 × 400 to 480V
Control Voltage: AC 230V ±10%
Frequency: 50 to 60 Hz
Drive Controller Current (4 kHz): 71 A
Drive Controller Current (8 kHz): 60 A
Continuous Power (4 kHz): 26 kW
Continuous Power (8 kHz): 22 kW
Peak Current: 71 A
Peak Power: 26 kW
Continuous Regenerated Power: 22 kW
Maximum Frequency (4 kHz): 800 Hz
Maximum Frequency (8 kHz): 1600 Hz
Heat Dissipation Constant Current: 900 W
Heat Dissipation Air Channel: 600 W
Protection Class: IP20
Cooling Mechanism: Built-in Blower
Weight: 49 kg
Bleeder Resistor: Not Included
Command Communication: SERCOS Interface
Motor Feedback: Digital Servo and Resolver Feedback
Numeric Control Function: 79
Basic Unit: DKR03.1-W100-B
Plug-in Boxes Slots: 5
Interfaces Used: U1 to U4
Software Module Slot: U5