Rated Current: 200 Amps
Valid Ambient Temperature: 5 to 45 degrees Celsius
Installation Elevation: 0 to 1000 meters
Maximum Operating Temperature: 55 degrees Celsius
Maximum Operating Altitude: 5000 meters
Load Factor at 55 degrees: 80% of nominal data
Load Factor at 5000 meters Altitude: 65% of nominal data
Enclosure Rating: IP 20
Cooling Method: Heat Sink and Blower
Weight: 104 kilograms
Dimensions: 1000 x 440 x 290 millimeters
Storage Temperature: -30 to 80 degrees Celsius
Feedback Mechanism: Digital servo and resolver feedback
Communication Interface: SERCOS
Dedicated Firmware: Ordered separately
Bleeder: Ordered separately.