Installation: Vertical only
Temperature threshold for air inlet: Not specified
Recommended air guide use: Yes
Recommended distance above and below: 125 millimeters
Dimensions: 206 x 95 x 170 millimeters
Weight: 1.9 kilograms
Storage temperature range: -25 to 70 degrees Celsius
Transport temperature range: -20 to 60 degrees Celsius
Input: Single phase at 200 Volts AC
Normal duty power rating: 750 watts
Output frequency range: 0 to 400 Hertz
Default carrier frequency: 6 kilohertz
Carrier frequency range: 1 to 15 kilohertz
Efficiency: Greater than 95%
Control: Standard vector control (SVC)
Speed regulation range: 1:200
Torque at start-up: 200% of rated torque
Control section: Flex-control with standard I/O
Standard communication interface: RS-485 serial interface
Additional communication interface: Modbus (factory installed)
Housing: IP 20 rating
EMC filter: Industrial area class C3
Display: 7-segment with potentiometer
Shipping: Global