Product Line Code: 0
Power Rating: 11kW
Jog Command: Higher priority than Run/Stop
Frequency Detection: Difference between output and setting frequencies
Protection Degree: IP 20
Control Section: Standard configuration
Power Supply Frequency: 50/60Hz +/-5% Tolerance
Start-up Torque: 200% of rated torque at 0.5Hz
DC Braking Time: 0-20s
Digital Outputs: One open collector output, one relay output
Operating Temperature: -10C to 45C
Temperature Derating: 1.5% for every 1C rise between 45C and 55C
Cooling Mechanism: Enforced air cooling
Communication Cables: Shielded twisted pair cables for RS 485
Output Terminals: U, V and W connected to motor
Mains Choke: Required if DC bus is connected in parallel
Max Charging Current: 50A
Relay Output: Inactive when no error
Analog Outputs: Voltage of 0V to 10V or Current of 0mA to 20mA
EN Protection Degree: 2.