1-888-551-3082 | 1-919-443-0207 | sales@indramat-usa.com

HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW

HCS IndraDrive Controllers

  Call for Quote
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping

The HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW from Bosch Rexroth Indramat features a line series HCS01 and IP20 protection. Part of the HCS IndraDrive Controllers series, it uses 3 x AC 110–230 V ±10% and internal air cooling. It supports SERCOS III master communication and the ADVANCED control section design.



Interfaces include IndraDyn Hiperface/EnDat 2.1/2.2 encoder and encoder emulation. Device peak current is 3 A. Firmware is ordered as a separate subposition.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Encoder emulation

Safety Interface
Not equipped

Line Series
HCS01

Mains Voltage
3 x AC 110...230 V ±10%

Device Peak Current
3 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

How does the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW manage heat during operation?

It uses internal air cooling via an integrated blower, eliminating the need for external cooling units. This simplifies installation in compact control cabinets.

What precautions should be taken when connecting 3-phase 110–230 V AC power?

Ensure balanced phase connections and proper grounding to prevent voltage imbalance. Overvoltage beyond ±10% can trigger protective shutdowns.

How does encoder emulation benefit system integration?

Encoder emulation allows the drive to output simulated encoder signals to other devices. This simplifies synchronization with legacy controllers or feedback loops.

How does the ADVANCED control section design impact functionality?

The ADVANCED design supports extended communication and control features. It allows higher-level diagnostics and multi-axis coordination.

Can the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW be used with existing IndraDyn motors?

Yes, it supports IndraDyn encoders with Hiperface and EnDat 2.1/2.2 protocols. This allows seamless integration with compatible Rexroth servo motors.

HCS011EW0003A02ACCECEMNNNNFW

HCS01 1E W0003 A 02 A CC EC EM NN NN FW

hcs03.1e-w0100-a-05-npbv

HCS1.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW

Internal Product Review

The HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW is a compact IndraDrive Controller from the Bosch Rexroth Indramat HCS01 line. It operates on 3 x AC 110–230 V ±10%, features internal air cooling, and includes SERCOS III master communication with ADVANCED control design. It is commonly used in automation systems, robotics, and packaging machinery.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0003-A-02-A-CC-EC-EM-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo