HCS01.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW from Bosch Rexroth Indramat features a mains voltage of 3 x AC 110...230 V ±10% and an IP20 rating. As part of the HCS IndraDrive Controllers it uses internal air cooling and supports SERCOS III master communication.
It provides STO and SBC safety interfaces and encoder connectivity via IndraDyn Hiperface/EnDat 2.1/2.2. The drive has a peak current of 3 A and operates as an infeeding/feeded unit.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
MultiEthernet
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
3 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How do the STO and SBC safety interfaces enhance operational safety?
STO cuts motor torque instantly during faults, while SBC ensures controlled braking when needed. Together, they meet machine safety standards without needing external safety relays.
Can the HCS01.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW operate with multiple motor encoder types?
Yes, it supports IndraDyn Hiperface and EnDat 2.1/2.2 encoder systems. This allows flexible integration with various motor feedback devices for precise motion control.
How should wiring be planned for its 3 x AC 110–230 V power input?
Cables must be rated for the specified voltage range and include proper grounding. Voltage imbalance or loose connections can cause communication faults or thermal issues.
What are the installation implications of its “infeeding/feeded” configuration?
It can both supply and receive energy within a drive system, optimizing power usage. This setup allows regenerative energy recovery and simplifies power distribution across axes.
How does limited environmental protection affect its maintenance requirements?
Because it lacks dust or moisture sealing, periodic cabinet cleaning and airflow checks are critical. This prevents particle buildup that could impair cooling efficiency or electronics lifespan.
Common Misspellings
HCS011EW0003A02ACCECETL4NNFW
HCS01 1E W0003 A 02 A CC EC ET L4 NN FW
hcs03.1e-w0150-a-05-lnbn
HCS1.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW
Internal Product Review
The HCS01.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW is a Bosch Rexroth Indramat drive controller from the IndraDrive series. It features internal air cooling, SERCOS III communication, and STO/SBC safety interfaces for reliable performance. Its IP20-rated housing is typically a compact metal enclosure suited for control cabinet installation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-A-CC-EC-ET-L4-NN-FW.
Want to 