HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
3 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Where should the HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW controller be positioned within the control cabinet to ensure optimal heat management?
It must be vertically mounted with 90mm clearance above and below, ensuring uniform airflow and preventing internal heat accumulation during prolonged operational hours.
Does the Bosch Rexroth HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW controller allow DC bus coupling through the X77 interface point?
No, it lacks DC bus coupling capability via X77, necessitating independent supply circuits when integrated within parallel multi-controller configurations.
How is the relay contact in the HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW controller wired for system feedback integrity?
It is connected in a normally closed configuration, transmitting operational feedback to supervisory logic systems for fault monitoring and status diagnostics.
What preventive measures does Bosch Rexroth recommend for condensation avoidance on the controller surface?
It maintain ambient humidity below 85% and temperature gradients within 5°C/hour to prevent surface condensation, which could impair dielectric strength and insulation.
What is the function of the cooling delay after power-off in the HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW controller?
The 15-minute cooling delay ensures thermal equilibrium dissipation, preventing thermal shock and maintaining component longevity after shutdown sequences.
Common Misspellings
HCS011EW0003A02BETECECL4NNFW
HCS01 1E W0003 A 02 B ET EC EC L4 NN FW
hcs03.1e-w0280-a-05-nnnn
HCS1.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW
Internal Product Review
The HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW controller from Bosch Rexroth Indramat part of the HCS series. It has 8W continuous power dissipation and parallel connectivity options with fuse protection. It is used for driving asynchronous and synchronous rotary or linear controllers in industrial automation systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-B-ET-EC-EC-L4-NN-FW.
Want to 