HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW from Bosch Rexroth Indramat features internal blower cooling and a multiEthernet interface. It’s part of the HCS IndraDrive Controllers and delivers 3 A peak current with a 3 × AC 110–230 V mains voltage.
It provides STO safety functionality, supports IndraDyn Hiperface or EnDat 2.1/2.2 encoders, and requires firmware ordered separately. The converter holds an IP20 rating and matches a BASIC control section design.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
3 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does the HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW controller manage input voltage fluctuation within ±10% range?
It employs an internal DC link and voltage monitoring circuit that compensates for transient variations, maintaining constant modulation for uninterrupted inverter section operation.
Where does the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW controller derive its switching frequency modulation scheme?
The controller utilizes a PWM sinusoidal algorithm driven by DSP logic that optimizes switching intervals to minimize harmonic distortion and thermal stress on the IGBTs.
What encoder interface protocols are supported by the HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW controller?
It supports multiencoder options including EnDat 2.2, SSI, and Hiperface, enabling simultaneous digital feedback synchronization for hybrid position and speed sensing architectures.
Does the Bosch Rexroth controller model HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW integrate thermal derating functionality?
Yes, it includes PTC sensor interfacing and internal heat sink monitoring to adjust switching duty cycle and prevent IGBT overtemperature excursions during extended duty cycles.
What is the short-circuit withstand capacity of the HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW controller?
The device sustains up to 42 kA RMS short-circuit current, leveraging fast semiconductor fuses and internal bus precharge limitation for arc-free isolation response.
Common Misspellings
HCS011EW0003A02BETECEPL3NNFW
HCS01 1E W0003 A 02 B ET EC EP L3 NN FW
hcs04.1e-f0500-a-05-nnbv
HCS1.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW
Internal Product Review
The Bosch Rexroth Indramat HCS Series controller model HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW delivers reliable industrial-grade performance. It supports 1 or 3-phase AC 110–230 V with 42 kA SCCR and ±10 % voltage tolerance. It is used in axis drive controllers and in flexible motion control systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-B-ET-EC-EP-L3-NN-FW.
Want to 