The Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW converter, part of the HCS IndraDrive Controllers series, delivers compact and efficient drive control for demanding industrial installations. Manufactured by Bosch Rexroth Indramat, this module supports a Mains Voltage of 3 x AC 110...230 V ±10% and features a Device Peak Current of 3 A. Its Cooling Method is Air, internal (through integrated blower), ensuring thermal stability in confined control cabinets. The unit's IP20 IP Rating protects internal electronics from dust ingress while maintaining accessibility for service. Designed within the Line Series HCS01, the product includes an integrated blower and a Power Supply Unit capable of both Infeeding / Feeded configurations for flexible system integration.
Featuring advanced communication and safety architectures, the controller employs a Communication Interface: MultiEthernet with dual sets of two yellow LED and two green LED displays for real-time network diagnostics. Its primary feedback path uses Interface 1 Type: Encoder IndraDyn Hiperface/EnDat 2.1/2.2, while Interface 2 Type is Not equipped, optimized for streamlined configurations. The Safety Interface is Not equipped in this design, but the device incorporates integrated safety technology within its firmware. The Control Section Design Type is specified as BASIC, with a corresponding Pairing Note indicating pairing with Control Section Design "BASIC" (B). As a modular component, the Firmware Order Note requires separate ordering of firmware sub-positions to match application demands.
Reliability is enhanced through a robust mounting scheme using two M6 × 20 screws and a dedicated strain relief for terminal connectors. Transport and storage tolerance spans 5% to 95% relative humidity without degradation of the integrated electrolytic capacitors. Motor encoder cabling is facilitated via a D-Sub female 15-pin connector, and a shielded plate arrangement ensures effective noise immunity. The controller's freely configurable digital inputs/outputs support customization in machine tool installations, such as wood machining or material processing. Retention of factory cable assemblies and avoidance of unauthorized hardware modification preserve warranty coverage and ensure compliance with the one-year Wake Industrial warranty for global dispatch.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
3 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Does the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller support redundant feedback channels?
No, this configuration utilizes a single primary feedback channel for IndraDyn encoders; redundancy can only be established through higher-level control architecture integration.
Where can the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller be physically installed for optimum airflow?
It should be mounted vertically in control cabinets with unobstructed ventilation, maintaining a minimum 100 mm clearance for the internal blower’s cooling efficiency.
How are fieldbus extensions managed on the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller without Interface 2?
They require optional communication add-ons via the system expansion slot; base units without Interface 2 rely on serial encoder communication only.
How is the IP20 protection rating implemented in the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller housing?
Its enclosure prevents accidental contact with internal conductors and ingress of solid particles over 12 mm, ensuring operator safety in cabinet setups.
Where does firmware storage occur inside the Bosch Rexroth Indramat HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller?
The firmware resides in embedded flash memory with CRC verification at startup to ensure code integrity and avoid operational corruption during runtime.
Common Misspellings
HCS011EW0003A02BETECNNNNAAFW
HCS01 1E W0003 A 02 B ET EC NN NN AA FW
hcs04.2e-w0300-n-06-nnbn
HCS1.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW
Internal Product Review
The HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW controller from the HCS series by Bosch Rexroth Indramat is engineered for precisional task. It features a 3 phase voltage as AC 110–230V at input, and internal air cooling. It is commonly applied in renewable systems, automation and grid energy management processes.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-B-ET-EC-NN-NN-AA-FW.
Want to 