HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW
HCS IndraDrive Controllers
The HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW from Bosch Rexroth Indramat offers a SERCOS III interface and internal air cooling via an integrated blower. Part of the HCS IndraDrive Controllers, it uses an ECONOMY control section design and supports a mains voltage of 3 × AC 110–230 V ±10%.
It features an infeeding/feeded power supply unit, a 3 A peak current, and IP20 protection. Firmware is ordered separately, and it employs an Encoder IndraDyn Hiperface/EnDat interface.
Technical Specifications
Communication Interface
SERCOS III
Pairing Note
Paired with Control Section Design 'ECONOMY' (E)
Control Section Design Type
ECONOMY
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
3 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Does the Bosch Rexroth HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW controller include integrated choke components for input filtering?
No, it requires external mains chokes for enhanced EMI suppression, although internal circuitry compensates basic harmonic distortion through filtering capacitors.
What are the communication interface protocols supported by Bosch Rexroth HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW controller hardware?
The hardware supports both Sercos III and EtherCAT topologies, offering deterministic cyclic communication for precise motion synchronization across distributed drives.
What form of power semiconductor devices are embedded in Bosch Rexroth HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW controller inverter bridge?
It integrates insulated-gate bipolar transistors (IGBTs) with low-loss switching characteristics for stable AC output generation under high-speed modulation.
How does the Bosch Rexroth HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW controller handle short-circuit protection?
It uses fast-acting current sensors and gate shutdown circuits that isolate affected phases within microseconds, preventing semiconductor failure.
What is the environmental protection capability of the Bosch Rexroth HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW controller?
It complies with IP20 standards, ensuring resistance to solid objects above 12 mm and minimal dust intrusion for indoor cabinet installations.
Common Misspellings
HCS011EW0003A02ES3ECNNNNAAFW
HCS01 1E W0003 A 02 E S3 EC NN NN AA FW
hcs04.2e-w1130-n-06-nnnn
HCS1.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW
Internal Product Review
The Bosch Rexroth Indramat controller HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW converter drive comes from the HCS series. It offers 0.75 kW power, 2–4 A output and operates on 254–748 V DC with reliable internal cooling. It finds its applications in aerospace machinery, power plants machinery and precise servo-control operations.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0003-A-02-E-S3-EC-NN-NN-AA-FW.
Want to 