The HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW drive controller by Bosch Rexroth Indramat belongs to the HCS IndraDrive Controllers series and is engineered as a compact converter for precise motion control in industrial automation. Featuring a Device Peak Current of 5 A, a nominal Mains Voltage range of 3 × AC 200…500 V ±10%, and an integrated blower for Air, internal (through integrated blower) cooling, this controller delivers reliable power conversion and temperature management. Its primary function is to regulate servo motor operation while ensuring safe torque off and brake control.



At its core, the controller utilizes a SERCOS III master (cross communication) interface for deterministic, real-time data exchange and supports a MultiEthernet interface for flexible network integration. Safety is assured with STO (Safe Torque Off) and SBC (Safe Brake Control) interfaces, while a dedicated Encoder IndraDyn Hiperface/EnDat 2.1/2.2 port provides precise feedback for servo loops. The unit’s IP20 rating protects internal electronics from solid contaminants, and the Control Section Design Type: ADVANCED ensures enhanced control algorithms. Its compact dimensions (215 mm × 196 mm × 50 mm) and 1.30 kg mass promote space-efficient installation.



Designed for robust operation, the drive controller requires 90 mm of clearance above and below for optimal airflow and operates in ambient temperatures from 0 °C to +40 °C. The build quality meets IP20 dust protection standards, while the integrated blower maintains efficiency without external fans. Firmware updates are managed via a separately ordered firmware sub-position, ensuring field upgradeability. Paired with the ADVANCED control section design, it supports high-performance machine cycles and complies with SERCOS safety communication protocols. In industrial applications, this converter enhances system uptime, improves motion precision, and simplifies networked drive integration, offering a durable and efficient solution for modern automation environments.

Technical Specifications

Communication Interface
SERCOS III master (cross communication)

Pairing Note
Paired with Control Section Design 'ADVANCED' (A)

Control Section Design Type
ADVANCED

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
MultiEthernet

Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
5 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What applications are suitable for the HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW controller?

The HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW controller excels in compact automation tasks like pick-and-place systems, packaging machinery, or gantry axes in assembly lines. Its real-time SERCOS linkage and safety features make it suitable for coordinated multi-axis motion.

Why is the nominal mains voltage range 3×AC 200–500 V ±10% important?

That voltage flexibility lets the controller adapt to different factory power supplies (e.g. 230 V, 400 V, 480 V). It ensures stable input under supply fluctuations (±10 %), essential for industrial environments.

What range of ambient temperature is typical for reliable operation?

The controller is designed to operate in ambient temperatures from 0 °C to +40 °C without derating. Operating outside this range may require reduced current or external cooling.

How does the STO interface protect the HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW controller?

The Safe Torque Off (STO) interface of HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW controller immediately disables torque generation when triggered, cutting power to the inverter stage. It ensures safe halting of the motor without mechanical braking.

Why is the multi-encoder interface (HIPERFACE/EnDat) valuable?

The multi-encoder interface allows precise feedback from different encoder types without additional hardware. It reduces wiring complexity while supporting systems such as EnDat 2.1, HIPERFACE, resolver, SSI.

HCS011EW0005A03ACCECETL4NNFW

HCS01 1E W0005 A 03 A CC EC ET L4 NN FW

hcs01.1e-w0003-a-02-a-cc-ec-ec-l4-nn-fw

HCS1.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW

Internal Product Review

Bosch Rexroth manufactured the HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW drive controller that offers exceptional reliability with a 5 A peak current, SERCOS III master communication, and STO/SBC dual safety. Its integrated blower cooling enhances heat dissipation under load. This drive controller ensures precise, secure, and synchronized multi-axis motion control across demanding automation systems.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0005-A-03-A-CC-EC-ET-L4-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo