HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW is a HCS Drive Controller by Bosch Rexroth Indramat, from the HCS IndraDrive Controllers series. It offers a SERCOS III master communication interface, pairs with an ADVANCED control section, and uses internal air cooling via an integrated blower. Rated IP20 and operating on 3 x AC 200...500 V ±10%, it delivers peak currents up to 5 A, supports encoder interfaces (Hiperface/EnDat 2.1/2.2) and PROFIBUS, and features STO safety.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
5 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does pairing with the ADVANCED control section benefit the controller?
The ADVANCED section supports extended motion functions (e.g. camming, gearing) and higher memory space. This increases flexibility beyond a basic control logic layer.
What role does the STO (Safe Torque Off) interface provide in this product?
The STO function enables safe disabling of motor torque without cutting power supply. It offers a certified safety measure for emergency shutdown scenarios.
What is the benefit of being rated for 3 × AC 200–500 V ±10 % in HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW drive controller product code?
The HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW drive controller offers wide input voltage tolerance, allowing stable operation across utility fluctuations. The ±10 % margin handles supply variation without triggering undervoltage faults.
Why are encoder interfaces like Hiperface/EnDat 2.1/2.2 supported in HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW drive controller ?
These high-resolution bi-directional encoder protocols of HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW drive controller provide precise feedback and diagnostics to the drive. That enables advanced closed-loop control and error detection.
Why is internal air cooling via integrated blower used instead of passive cooling?
Active cooling via blower ensures effective heat dissipation at higher load cycles even in compact enclosures. It maintains junction temperature stability under peak current usage.
Common Misspellings
HCS011EW0005A03ACCECPBL3NNFW
HCS01 1E W0005 A 03 A CC EC PB L3 NN FW
hcs01.1e-w0003-a-02-a-cc-ec-et-s4-nn-fw
HCS1.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW
Internal Product Review
The HCS01.1E‑W0005‑A‑03‑A‑CC‑EC‑PB‑L3‑NN‑FW by Bosch Rexroth Indramat combines SERCOS III, PROFIBUS, Hiperface/EnDat 2.x, and STO safety in a compact drive. With 5 A peak current, internal blower cooling, and deterministic real-time control, it ensures reliable, precise motion and full safety compliance for advanced automation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-A-CC-EC-PB-L3-NN-FW.
Want to 




