HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
5 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What role does the ±10 % tolerance on 3× AC 200–500 V play?
The ±10 % margin permits the drive to withstand input voltage fluctuations or supply imbalances. Thus HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW controller remains stable in power systems with minor voltage sag or overvoltage events.
What is the purpose of “infeeding / feeded” DC bus capability?
That mode lets the drive either draw from or supply energy back to the shared DC bus. In multi-axis systems, HCS01.1E-W0005 can recuperate braking energy to other drives or the source.
How is the device protected given its IP20 rating?
IP20 ensures protection from solid foreign objects >12 mm, but not from liquid ingress. Thus HCS01.1E-W0005 must be mounted within a dust-protected cabinet/environment.
In which industrial application is HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW controller commonly used?
The HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW controller is often deployed in CNC axes, robotic joints, or high-speed pick-and-place systems. The HCS01.1E-W0005 variant suits smaller single-axis machines, providing precise servo control and tight feedback loops under 5 A peak.
Why choose MultiEthernet rather than conventional fieldbus in HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW controller?
The MultiEthernet interface of HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW controller enables low-latency, deterministic cyclic data exchange, improving synchronization across axes. It allows more flexible network topologies and aligns with modern industrial Ethernet standards.
Common Misspellings
HCS011EW0005A03AETECDANNNNFW
HCS01 1E W0005 A 03 A ET EC DA NN NN FW
hcs01.1e-w0003-a-02-a-cc-ec-nn-s4-nn-fw
HCS1.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW
Internal Product Review
The HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW drive controller is engineered for high precision and efficiency. Its MultiEthernet communication capability allows seamless integration into modern industrial networks. The internal air cooling system ensures optimal performance under varying loads. With a peak current capacity of 5 A, it meets the demands of advanced motion control applications.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-A-ET-EC-DA-NN-NN-FW.
Want to 