HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
5 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Why is the internal blower cooling used in HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW drive effective compared to passive cooling?
The active blower of HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW drive forces airflow across the internal heat sinks, keeping junction temperatures lower under higher load. It enables continuous output even when ambient temperatures rise.
How does the STO (Safe Torque Off) interface enhance system safety in HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW drive?
The STO interface of HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW drive immediately disables torque generation when engaged, preventing unintended motor drive. It ensures compliance with safety standards like SIL2/PL d without stopping all electronics.
How does MultiEthernet differ from a single-protocol interface on this controller?
The multiEthernet allows runtime switching among EtherCAT, PROFINET, EtherNet/IP, etc. It offers flexibility in control network topology without swapping hardware.
In which applications is this drive controller commonly deployed?
The controller is ideal for handling systems, packaging machines, pick-and-place axes, and compact automation modules. Its compact design and modular communication make it suited for OEM panel systems.
What is the continuous current capability of HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW drive at 16 kHz switching?
At fs = 16 kHz, the typical continuous output current is limited (approx 0.5 A) per datasheet. This illustrates trade-offs between switching speed and continuous current capacity.
Common Misspellings
HCS011EW0005A03AETECNNL3NNFW
HCS01 1E W0005 A 03 A ET EC NN L3 NN FW
hcs01.1e-w0003-a-02-a-cc-ec-pb-l4-nn-fw
HCS1.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW
Internal Product Review
The HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW controller delivers reliable performance with MultiEthernet communication and internal air cooling. Its Safe Torque Off (STO) safety interface ensures operational safety. Supporting IndraDyn encoders, it's suitable for precise motor control applications.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-A-ET-EC-NN-L3-NN-FW.
Want to 