HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW is a robust HCS Drive Controller from the HCS IndraDrive Controllers series. It features MultiEthernet communication, STO (Safe Torque Off) interface, and delivers 5 A peak current on 3 x AC 200–500 V ±10%. The air-cooled IP20 design with integrated blower, BASIC control section (version 1) pairing, and separate firmware order ensures flexible integration with IndraDyn Hiperface/EnDat encoders.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
5 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Can HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW drive linear motors or just rotary ones?
Yes. The HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller supports both rotary and linear motor types, as long as encoder and current requirements are met. Applications include gantries and direct-drive linear axes.
How is the “5 A peak current” rating determined for HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller?
The 5 A of HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller is measured during short peak periods (transient load), not continuous output. Continuous current capability is lower and depends on cooling and thermal limits.
Why does HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller-B use a multi-encoder interface rather than a single one?
A multi-encoder interface allows evaluation of HIPERFACE and EnDat encoders simultaneously or as fallback, improving redundancy and flexibility. It supports fault tolerance and encoder switchover.
What is the role of the BASIC control section in this controller drive?
The BASIC section provides core motion and I/O functions without advanced safety or diagnostics layers. It reduces complexity and cost when full advanced functions are not needed.
Why is STO (Safe Torque Off) included in the HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller?
The STO interface of HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW controller provides immediate disconnection of motor torque without full power removal, enhancing functional safety. It allows safe stopping under fault or emergency conditions without interrupting DC bus.
Common Misspellings
HCS011EW0005A03BETECECL3NNFW
HCS01 1E W0005 A 03 B ET EC EC L3 NN FW
hcs01.1e-w0003-a-02-b-et-ec-cn-s4-nn-fw
HCS1.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW
Internal Product Review
Bosch Rexroth Indramat develops the HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW drive controller that delivers a 5 A peak current and features MultiEthernet communication. Its Safe Torque Off (STO) enhances safety. It is designed for 3-phase AC 200–500 V input which confirms the reliable performance in CNC and packaging industrial applications.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-B-ET-EC-EC-L3-NN-FW.
Want to 