HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW
HCS IndraDrive Controllers
The HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW drive controller from Bosch Rexroth Indramat forms a key element of the HCS IndraDrive Controllers series. This Product Type is part of the Line Series HCS01 and supports a three-phase input voltage of 3 x AC 200...500 V ±10%. It features an IP20 protection rating and delivers a Device Peak Current of 5 A with a maximum inrush current of 3.3 A at a Control Voltage Input of 24 V DC. The controller relies on an Air, internal (through integrated blower) Cooling Method and draws only 27 W of power under standard conditions. The Power Supply Unit configuration can function as either infeeding or feeded, offering flexible integration options. The compact converter design follows Design Version 1 and pairs with Control Section Design Type BASIC (Paired with Control Section Design 'BASIC' (B)).
Performance is optimized through a rich set of interfaces and technical features. Communication is handled via MultiEthernet with a Communication Interface that ensures low-latency network control. Position feedback is supported through Encoder IndraDyn Hiperface/EnDat 2.1/2.2 on Interface 1 Type, while Interface 2 Type remains not equipped unless specified. Functional safety is maintained via the integrated STO (Safe Torque Off) Safety Interface. Transient response is governed by a current pulse width of 2 ms and an input capacitance of 0.04 millifarads. The controller supports mains frequencies of 50 to 60 Hz with a maximum rate of change of 2 Hz/s and requires 14 AWG wiring for AC input. Additional parameters include a single-line display, four-button keypad for diagnostics, and a slot for SD card–based firmware updates.
Reliability in industrial environments is assured through internal blower cooling and back-side mounting directly to the cabinet surface. The HCS01.1E series operates reliably in ambient temperatures from 0 to 40°C and dissipates heated air within the control cabinet to maintain stable thermal conditions. Installation by trained personnel minimizes errors and leverages the controller’s clear front-panel indicators for status, error codes, and pending warnings. With its compact footprint and robust IP20 enclosure, the unit integrates seamlessly into automated systems for packaging, material handling, and precision motion control. The modular design and support for safety functions make it ideal for applications demanding both performance and compliance with modern safety standards.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
5 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
Why is STO (Safe Torque Off) important in HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW controller?
The STO interface of HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW controller disables torque generation without removing supply voltage internally. It ensures safe quick stoppage in case of emergency or fault conditions.
How does the blower cooling improve performance?
The blower ensures forced internal airflow across heat sinks, enabling sustained operation under full load. It prevents thermal derating even when ambient temperatures approach limits.
What system architectures commonly employ HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW controller?
The HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW controllers are typically used in CNC, robotic joints, and packaging lines, forming axes controlled via fieldbuses. Their modularity and communication flexibility make them ideal in distributed motion systems.
How does IP20 rating affect deployment environments?
The IP20 rating means protection against solid objects >12 mm but no moisture ingress protection. So the device must be installed in an enclosure in humid or dusty environments.
How is power switching managed in this drive controller?
The power stage uses insulated gate transistors (IGBTs) to modulate voltage to the motor. The controller precisely regulates current loops and employs internal DC-link management.
Common Misspellings
HCS011EW0005A03BETECNNL3NNAW
HCS01 1E W0005 A 03 B ET EC NN L3 NN AW
hcs01.1e-w0003-a-02-b-et-ec-nn-l3-nn-fw
HCS1.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW
Internal Product Review
Bosch Rexroth manufactures the HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW drive controller that is used in industrial automation applications. Its MultiEthernet communication ensures seamless network integration, while Safe Torque Off (STO) enhances safety. It is ideal for precision conveyor and material handling systems and delivers 5 A peak current with internal air cooling.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0005-A-03-B-ET-EC-NN-L3-NN-AW.
Want to 