The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller from Bosch Rexroth Indramat’s HCS IndraDrive Controllers series combines compact design with advanced drive control. It has internal air cooling via an integrated blower, MultiEthernet communication, IP20 protection, and a peak output current of 5 A. The unit supports safe torque off and safe brake control and works with encoder interfaces like Hiperface and EnDat. Firmware is ordered separately and it pairs with Control Section Design BASIC.

Technical Specifications

Communication Interface
MultiEthernet

Pairing Note
Paired with Control Section Design 'BASIC' (B)

Control Section Design Type
BASIC

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
5 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

Why is the 3×AC 200-500 V ±10 % input range useful?

The broad voltage tolerance covers European, American, and Asian mains standards (e.g. 230 V, 400 V) and allows ±10 % fluctuation without derating. It increases robustness to supply disturbances.

What role does the STO and SBC safety interface play?

The drive’s STO (Safe Torque Off) and SBC (Safe Brake Control) prevent torque generation and command brake release during fault or emergency conditions. These safety functions help meet machine safety standards.

How does the internal blower cooling benefit in tight cabinets of HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?

The integrated blower of HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller ensures forced-air convection inside the controller enclosure, allowing compact mounting without external fans. It also maintains thermal stability up to rated current.

What is the target application domain for HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller?

The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller is aimed at automation, handling, pick-and-place, packaging, and machine tool tasks which demand compact servo control

What diagnostics and fault reporting does this model support?

The drive includes built-in diagnostics for overcurrent, overheating, shorted motor winding, and sensor errors. It reports faults via the network interface and internal status registers.

HCS011EW0005A03BETECNNL4AAFW

HCS01 1E W0005 A 03 B ET EC NN L4 AA FW

hcs01.1e-w0003-a-02-b-et-ec-nn-l4-nn-fw

HCS1.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW

Internal Product Review

The HCS01.1E-W0005-A-03-B-ET-EC-NN-L4-AA-FW controller is manufactured by Bosch Rexroth have a stable MultiEthernet communication, STO/SBC safety support, and clean internal airflow cooling achieving IP20 protection. It reliably drives servo axes at 3 × AC 200–500 V input. Its modular firmware architecture and encoder flexibility make it a robust choice for high-precision automation.