The Bosch Rexroth Indramat HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW drive controller from the HCS IndraDrive Controllers series is a high-performance HCS Drive Controller designed for flexible motion control. It features a SERCOS III master (cross communication) interface, STO (Safe Torque Off) safety, and dual encoder interfaces supporting IndraDyn Hiperface/EnDat 2.1/2.2. Paired with Control Section Design 'ADVANCED', it uses an integrated blower for air, internal cooling and operates on 3 x AC 110...230 V ±10% mains voltage. Rated for a Device Peak Current: 6 A with IP20 protection, this version 1 design requires separate firmware ordering and offers infeeding/feeded power supply.
Technical Specifications
Communication Interface
SERCOS III master (cross communication)
Pairing Note
Paired with Control Section Design 'ADVANCED' (A)
Control Section Design Type
ADVANCED
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
6 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What ensures accurate motion in the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW?
Its dual encoder system delivers precise position feedback. This synchronization guarantees smooth and accurate multi-axis coordination.
How does the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW manage cooling?
Internal air circulation distributes heat evenly across electronic components. This improves reliability during prolonged operation.
What’s the safety feature included in the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW?
It comes with Safe Torque Off functionality. This instantly halts motor torque during emergencies to ensure operator safety.
Is the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW firmware user-controlled?
Yes, firmware is separately installed. Users can easily update or fine-tune drive parameters for better control performance.
What is the protection level of the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW?
The IP20-rated case shields sensitive electronics. This ensures longer service life even in industrial environments.
Common Misspellings
HCS011EW0006A02ACCECECL3NNFW
HCS01 1E W0006 A 02 A CC EC EC L3 NN FW
hcs01.1e-w0005-a-03-a-cc-ec-et-s5-nn-fw
HCS1.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW
Internal Product Review
The HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW ensures synchronized performance with its dual encoder inputs and STO safety. This is a dependable drive for demanding systems where accuracy and safety heat management are crucial for consistent long-term operation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0006-A-02-A-CC-EC-EC-L3-NN-FW.
Want to 