Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 110...230 V ±10%
Device Peak Current
6 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What safety functions are included in the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW?
It features STO (Safe Torque Off), a safety interface that prevents unintended motor activation. This ensures equipment protection and operator safety during maintenance or emergency stops.
How does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW handle heat management?
The internal air-cooling system uses a blower to regulate temperature. This design promotes steady airflow and prevents thermal overload, ideal for continuous-duty environments.
What network capabilities does the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW provide?
MultiEthernet supports fast, real-time communication across multiple protocols. It ensures flexible integration with various PLC systems and reduces latency between drives and controllers.
What are the voltage and current ratings of the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW?
It runs on 3 × AC 110–230 V ±10% mains and provides a peak current of 6 A. This allows stable torque delivery for compact servomotor applications.
How does the drive ensure compatibility across systems?
It pairs with the BASIC control section and supports firmware modularity. This structure simplifies upgrades, reduces integration errors, and maintains consistency across production setups.
Common Misspellings
HCS011EW0006A02AETECNNL3NNFW
HCS01 1E W0006 A 02 A ET EC NN L3 NN FW
hcs01.1e-w0005-a-03-b-et-ec-ec-l3-nn-fw
HCS1.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW integrates MultiEthernet communication with built-in STO safety for protected operations. Designed for 3-phase power systems, it supports 6 A peak current and internal air cooling, combining reliability with space-efficient control performance in automated setups.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0006-A-02-A-ET-EC-NN-L3-NN-FW.
Want to 