HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW from Bosch Rexroth Indramat features an internal blower cooling method and delivers a device peak current of 8 A. Part of the HCS IndraDrive Controllers, it accepts a three-phase AC input voltage of 200–500 V ±10 % in an IP20 housing.
It supports switching frequencies from 4 to 16 kHz and has a capacitance to housing of 2×68 nF. Firmware must be ordered separately and the design version is 1.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does MultiEthernet simplify integration for HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
MultiEthernet on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW allows direct Ethernet-based connections to PLCs and SCADA, removing gateway needs. That reduces wiring complexity and shortens the path from installation to first-run validation for machine builders.
Why pair HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW with BASIC control?
BASIC pairing simplifies parameter space on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW, offering a dependable baseline for common axis tasks. This reduces commissioning time and minimizes configuration errors while preserving essential tuning options for final adjustments.
How does internal air cooling support reliability of HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
The blower on HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW keeps power electronics within rated temperatures during continuous operation. Good cabinet airflow design and intake filtration prevent thermal throttling and reduce the risk of temperature-related faults.
What does IP20 require when deploying HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW?
IP20 necessitates mounting HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW inside a protective cabinet in indoor settings to avoid moisture and fine dust. Where the environment is challenging, add enclosures or filters to retain warranty and reliable operation.
What advantage does HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW give machine builders under tight schedules?
Its BASIC-focused feature set, MultiEthernet connectivity and cabinet-ready packaging shorten integration and validation phases. This predictability enables quicker FATs and accelerated delivery while minimizing the need for custom engineering during handover.
Common Misspellings
HCS011EW0008A03BETECDANNNNFW
HCS01 1E W0008 A 03 B ET EC DA NN NN FW
hcs01.1e-w0006-a-02-b-et-ec-nn-l4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW
Internal Product Review
The HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW is a BASIC-paired MultiEthernet converter engineered for fast commissioning and predictable motion. Its cabinet-ready form and simplified feature set help machine builders deliver reliable axis control without deep custom tuning.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-DA-NN-NN-FW.
Want to 