1-888-551-3082 | 1-919-443-0207 sales@indramat-usa.com

HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW

HCS IndraDrive Controllers

  Call for Quote
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping

HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW, Bosch Rexroth Indramat, HCS IndraDrive Controllers represents a compact, high-performance converter within the HCS1 Compact Converter Series. It precisely regulates motor speed, position, and torque for synchronous, asynchronous, and linear servo motors. Employing a robust IP20 enclosure and internal blower, this converter integrates seamlessly into industrial control cabinets rated to IP54, safeguarding sensitive electronics from dust and contaminants. A clear operator panel provides real-time status feedback and simplifies parameter entry for efficient commissioning and diagnostics.



The controller accepts a wide Mains Voltage range of 3 x AC 200…500 V ±10% and delivers up to Device Peak Current of 8 A through its infeeding/feeded Power Supply Unit. Internal air cooling via an integrated blower ensures stable thermal performance under continuous load. Dual encoder ports (Interface 1 Type and Interface 2 Type: Encoder IndraDyn Hiperface/EnDat 2.1/2.2) enable high-resolution feedback for closed-loop control. Native Communication Interface on MultiEthernet allows low-latency network integration, while the Control Section Design Type “BASIC” simplifies pairing (Pairing Note: paired with Control Section Design “BASIC (B)”). Design Version 1 provides standardized firmware deployment (Firmware Order Note: firmware must be ordered as separate sub position).



Engineers benefit from tool-free rack mounting and plug-and-play encoder connections that accelerate system integration. The compact Line Series HCS01 footprint and optimized airflow path enhance reliability, reducing maintenance intervals. Ideal for high-precision applications in packaging, assembly automation, and CNC machinery, this converter delivers consistent performance at installation heights up to 1000 meters above sea level.

Technical Specifications

Communication Interface
MultiEthernet

Pairing Note
Paired with Control Section Design 'BASIC' (B)

Control Section Design Type
BASIC

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
8 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What does BASIC pairing mean operationally for HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?

BASIC pairing provides a lean parameter set for typical axis tasks on HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW, lowering setup complexity and standardizing behavior across similar machines. This streamlines both commissioning and in-field troubleshooting.

How reliable is the internal blower cooling on HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?

The blower enforces constant airflow over hot spots in HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW, stabilizing junction temperatures during continuous duty. Adequate filtration and cabinet ventilation prevent thermal throttling and ensure consistent performance.

What environment constraints follow from IP20 for HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?

IP20 mandates indoor cabinet mounting for HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW, excluding exposure to liquids or fine particulates. Where the area is dusty or humid, apply enclosures and filtered intakes to preserve electronics and blower function.

Which encoder standards work with HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW and why choose them?

HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW supports IndraDyn Hiperface and EnDat, enabling accurate position and diagnostic feedback. These protocols give engineers the signal clarity necessary for tight loop tuning and consistent motion fidelity.

What energy benefits does infeeding/feeded architecture provide for HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW?

The infeeding/feeded capability lets regenerative energy be returned to the DC bus or shared among drives, reducing wasted braking energy. In cyclic applications this lowers resistor loads, improves efficiency and decreases thermal stress on power handling components.

HCS011EW0008A03BETECECL2NNFW

HCS01 1E W0008 A 03 B ET EC EC L2 NN FW

hcs01.1e-w0006-a-02-b-et-ec-nn-nn-aa-fw

HCS1.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW

Internal Product Review

Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW centers on MultiEthernet communications for deterministic supervisory links. The network-first approach reduces gateway needs and eases connection to heterogeneous plant systems, improving telemetry exchange and control coordination across production cells.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EC-L2-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo