HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What safety functionality does the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW include?
The drive includes Safe Torque Off to remove torque-producing capability upon safety triggers, preventing movement. This reduces the need for additional torque-cut devices and simplifies compliance with machine safety regulations.
How does MultiEthernet help when deploying the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW on older lines?
MultiEthernet allows the drive to integrate with contemporary supervisory systems without extensive rewiring, making it suitable for retrofits that require modern telemetry and control while retaining much of the legacy hardware.
What are the thermal advantages of the integrated blower in the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW?
The blower targets critical heat-generating components, ensuring uniform temperature distribution and preventing hotspots. This design reduces thermal stress and lengthens component service life in continuous operation environments.
What installation best practices suit the IP20-rated HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW?
Install within ventilated cabinets with filtered intake and adequate space for airflow; avoid mounting in areas with fine particulate or liquid exposure. Proper cabinet design maximizes cooling efficiency and protects electronics.
Why is BASIC control section pairing often chosen for the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW?
BASIC pairing simplifies parameter sets and speeds commissioning for standard applications, reducing engineering time while keeping necessary motion tuning accessible. This approach is efficient for production machines with repeatable motion requirements.
Common Misspellings
HCS011EW0008A03BETECECL3NNNW
HCS01 1E W0008 A 03 B ET EC EC L3 NN NW
hcs01.1e-w0006-a-02-b-et-ec-nn-s4-nn-aw
HCS1.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW is engineered for essential safety operations with Safe Torque Off and reliable MultiEthernet connectivity. Its compact converter architecture and focused feature set are suitable for retrofits and OEM lines seeking standard safety compliance combined with modern network interoperability.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EC-L3-NN-NW.
Want to 