HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW from Bosch Rexroth Indramat is a drive controller with 3 x AC 200-500 V supply and 8 A peak current. Part of the HCS IndraDrive Controllers series, it has IP20 protection and internal blower cooling. This converter supports MultiEthernet and features STO and SBC safety functions.
Paired with BASIC design, it belongs to the HCS01 line. It has an IndraDyn Hiperface/EnDat encoder. Firmware is ordered separately.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How do STO and SBC operate together on the HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW to increase safety?
STO removes the drive’s ability to generate torque while SBC commands mechanical brakes to engage, providing electronic and mechanical restraint. Together they provide layered protection that is vital for large inertial loads or suspended mechanisms where torque removal alone is insufficient.
What network benefits does MultiEthernet provide to HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW?
MultiEthernet allows direct connections to a variety of Ethernet-based controllers and supervisory systems, supporting both deterministic command paths and high-bandwidth telemetry.
How does dual encoder support improve fault detection on HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW?
Dual encoders enable cross-checks and redundancy so discrepancies can be detected quickly; the drive can trigger alarms or fall back to safe modes upon mismatch. This increases system resilience and reduces the risk of undetected encoder faults causing process errors.
What mounting and cabinet considerations does IP20 require for HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW installations?
Mount the unit inside ventilated cabinets with filtration to keep out dust and moisture while maintaining adequate clearance for airflow. Proper cabinet design is crucial to maintain cooling performance and to meet safety and serviceability needs.
Why is BASIC control section pairing practical for HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW in production lines?
BASIC pairing reduces configuration complexity, enabling faster commissioning while preserving essential parameters for precise motion and safety configuration. This balance is useful for OEMs delivering repeatable machines that require robust stops and accurate position control.
Common Misspellings
HCS011EW0008A03BETECECL4NNFW
HCS01 1E W0008 A 03 B ET EC EC L4 NN FW
hcs01.1e-w0006-a-02-b-et-ec-nn-s4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW
Internal Product Review
The HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW pairs Safe Torque Off with Safe Brake Control to deliver redundant safety for motion arrest. Coupled with MultiEthernet and dual encoder ports, the module supports high-integrity stop events and precise position verification in demanding industrial systems.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EC-L4-NN-FW.
Want to 