HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW controller from the HCS IndraDrive Controllers series, manufactured by Bosch Rexroth Indramat, delivers high-precision motion control in a compact package. It operates on 3 x AC 200...500 V ±10% mains and can supply a device peak current of 8 A for rapid acceleration. Paired with Control Section Design ‘BASIC’ (B), as noted in the Pairing Note, the controller simplifies system integration. As a 1 design version, firmware alignment and maintenance are unified across all units.
Featuring a MultiEthernet communication interface, the HCS01.1E-W0008-A… synchronizes multi-axis drives with minimal latency. Redundant encoder feedback is provided by identical IndraDyn Hiperface/EnDat 2.1/2.2 ports on both Interface 1 and Interface 2, ensuring precise motion loops. Internal air cooling via an integrated blower maintains optimal thermal conditions within the IP20 rated enclosure. The unit is not equipped with a safety interface, focusing system resources on drive performance, while its infeeding/feeded power supply unit design supports flexible cabinet layouts.
The controller integrates seamlessly into Bosch Rexroth’s Line Series HCS01 ecosystem, enabling rapid commissioning and plug-and-play expansion. Its robust IP20 housing and integrated blower ensure reliable operation under continuous load. With a BASIC control section and consistent firmware versioning workflow, uptime and maintenance are optimized for industrial applications.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What redundancy features exist on HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW?
The drive supports redundant feedback strategies by exposing multiple encoder ports that can be cross-validated for fault tolerance. This capability reduces single-point encoder failures and allows fallback modes that maintain controlled operation until repairs are scheduled.
How should thermal behaviour be validated for HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW?
Run thermal profiling under expected duty cycles, monitor junction and cabinet temperatures to determine steady-state conditions. Use these measurements to finalize ventilation strategy and to set alarm thresholds for proactive thermal protection.
What network considerations matter when integrating HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW?
Ensure deterministic motion traffic and supervisory telemetry are separated on the network where applicable and validate cycle timing under load. Proper network segmentation prevents non-deterministic traffic from impacting real-time control loops.
How does the integrated blower affect expected maintenance intervals for HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW?
The blower simplifies cooling but introduces a mechanical component that requires periodic inspection and cleaning. Schedule blower checks and intake cleaning during preventive maintenance to avoid accumulated dust impacting cooling capacity.
What commissioning checks ensure the encoder paths are reliable for HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW?
Test each encoder channel for signal amplitude and error flags, perform closed-loop step tests and confirm fault propagation maps. Capture encoder diagnostics and parameter snapshots to ensure consistent setups across multiple drives.
Common Misspellings
HCS011EW0008A03BETECECNNNNFW
HCS01 1E W0008 A 03 B ET EC EC NN NN FW
hcs01.1e-w0006-a-02-b-et-ec-nn-sb-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW prioritizes predictable closed-loop performance via redundant encoder connectivity, delivering stable control in dense cabinet layouts. The integrated blower cooling maintains steady junction temperatures for continuous operation, thus easing commissioning and long-term thermal management.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EC-NN-NN-FW.
Want to 