HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW from Bosch Rexroth Indramat uses internal air cooling and accepts 3 x AC 200-500 V ±10%. Part of the HCS IndraDrive Controllers series, it delivers an 8 A peak current and features an integrated blower. This IP20-rated converter offers MultiEthernet communication and a basic control design.
It includes STO safety and supports encoder emulation. Firmware ordered separately. Integrated brake current measurement.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
Safety Interface
STO (Safe Torque Off)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What networking advantages does the HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW provide?
MultiEthernet support enables direct integration with multiple Ethernet-based protocols without external protocol converters. This reduces hardware complexity and shortens commissioning time when connecting the drive to diverse plant controllers and HMIs.
How can the HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW support remote diagnostics?
This high-rate telemetry exposes drive health metrics, alarm states and operating trends to supervisory systems. Remote access to these metrics enables condition-based maintenance planning and reduction of onsite troubleshooting time.
What cabinet ventilation best practices apply to the HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW?
Provide filtered intake and controlled exhaust to maintain stable cabinet temperatures and prevent dust ingress. Monitor internal cabinet temperature and ensure fans are sized for cumulative heat dissipation across all mounted components.
How should firmware be managed on the HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW?
Firmware must be selected and validated in staging prior to fleet rollout. Use documented rollout plans, version control and rollback procedures to minimize disruption and guarantee compatibility with host systems.
What grounding and cabling practices optimize performance for the HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW?
Use a dedicated low-impedance protective earth and separate power from signal routing to reduce interference. Proper shielding and bonding of encoder and communication cables prevent noise ingress that could corrupt feedback and network traffic.
Common Misspellings
HCS011EW0008A03BETECEML3NNFW
HCS01 1E W0008 A 03 B ET EC EM L3 NN FW
hcs01.1e-w0006-a-02-e-s3-ec-ep-l4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EC-SB-NN-FW prioritizes MultiEthernet connectivity to simplify integration across mixed automation networks. This network-optimized telemetry enables remote diagnostics and streamlined commissioning, reducing protocol translation overhead in complex plant topologies.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EM-L3-NN-FW.
Want to 