HCS01.1E-W0008-A-03-B-ET-EC-EM-NN-NN-FW
HCS IndraDrive Controllers
The HCS01.1E-W0008-A-03-B-ET-EC-EM-NN-NN-FW is an HCS Drive Controller from Bosch Rexroth Indramat’s HCS IndraDrive Controllers series. It supports MultiEthernet communication and pairs with the BASIC control section design. Featuring air internal cooling via an integrated blower, it operates on 3 x AC 200...500 V ±10% with a peak current of 8 A. The IP20-rated unit includes Encoder IndraDyn Hiperface/EnDat 2.1/2.2 and encoder emulation interfaces, and requires firmware ordered separately.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Encoder emulation
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does dual-layer safety operate on the HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW?
STO removes torque capability while SBC issues a command to engage mechanical brakes, creating overlapping protective measures. This layered approach ensures physical restraint in situations where electronic torque removal alone might not be sufficient.
What commissioning checks are required for SBC on the HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW?
Validate brake actuation timing, control signal integrity and coordinated behavior with STO under simulated fault conditions. Measure and record actuation times to confirm compliance with safety requirements and to tune brake control logic.
How should the HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW be documented for safety audits?
Include functional test records for STO and SBC, wiring diagrams and validation reports in the machine safety file. Traceable documentation demonstrates adherence to safety standards and supports regulatory review.
How does MultiEthernet support safety-related telemetry for the HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW?
Use segregated channels or VLANs to transmit safety event logs and brake states to supervisory systems, ensuring prompt operator notification. Prioritize safety traffic so that critical messages are relayed with minimal latency.
What design guidance improves arrest reliability when using the HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW with heavy loads?
Combine SBC with appropriately rated mechanical brakes and verify energy absorption calculations for worst-case stops. Account for residual energies in the drivetrain and design brake sizing and control logic accordingly.
Common Misspellings
HCS011EW0008A03BETECEMNNNNFW
HCS01 1E W0008 A 03 B ET EC EM NN NN FW
hcs01.1e-w0006-a-02-e-s3-ec-nn-l4-aa-fw
HCS1.1E-W0008-A-03-B-ET-EC-EM-NN-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EM-L4-NN-FW is an ideal choice for consistent performance. It pairs Safe Torque Off with Safe Brake Control to provide dual-layer stopping assurance. Electronic torque removal combined with mechanical brake command secures heavy-axis systems during faults and power loss.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EM-NN-NN-FW.
Want to 