HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW
HCS IndraDrive Controllers
The HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW from Bosch Rexroth Indramat offers a MultiEthernet interface and internal blower cooling. Part of the HCS IndraDrive Controllers series, it includes STO and SBC safety functions and pairs with a BASIC control section design. This controller accepts 3×AC 200–500 V and delivers peak current of 8 A.
It is rated IP20 and uses Hiperface/EnDat encoder interface. The device is version 1 with power supply. It belongs to the HCS01 series and offers torque off.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does STO function on the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW to provide emergency stops?
STO removes the drive’s capability to generate torque when a safety condition is asserted, ensuring motors cannot produce motion. This rapid torque cut is central to personnel safety during maintenance cycles and emergency events.
What panel density benefits does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW offer?
Its compact converter footprint preserves valuable cabinet space while still providing the necessary safety function. This enables denser control layouts for OEMs with constrained panel real estate.
How should thermal performance be monitored on the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW?
Track operating temperatures during representative duty cycles and inspect the blower periodically for dust buildup or bearing wear. Predictable thermal management preserves component life and prevents thermal derating.
How does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW interact with supervisory safety systems?
The drive reports safety state and alarms over the network, allowing supervisory systems to log events and alert operators. Integrate these signals into the safety management workflow for rapid incident acknowledgement and response.
What commissioning documentation is recommended for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW?
Provide test records of STO functions, wiring schematics, firmware revision notes and baseline parameter exports. These deliverables support traceable installations and make future audits and modifications straightforward.
Common Misspellings
HCS011EW0008A03BETECEPL4NNAW
HCS01 1E W0008 A 03 B ET EC EP L4 NN AW
hcs01.1e-w0008-a-03-a-cc-ec-cn-l3-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-EP-L3-NN-FW combines Safe Torque Off with compact packaging to enable compliant emergency stops in high-density control cabinets. It supports safe maintenance without compromising panel space or thermal performance.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-AW.
Want to 