HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
How does the HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW integrate into plant networks?
It uses MultiEthernet to interface directly with a variety of Ethernet-based controllers and supervisory systems, reducing protocol conversion. Proper network planning such as VLAN segregation and QoS helps prioritize motion traffic and keep latency low.
What are best practices for ventilation when installing HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
Provide filtered cabinet intake and ensure the blower’s airflow path is unobstructed; allow clearance for service access. Regularly inspect and clean inlet filters and the blower to prevent heat buildup and preserve consistent thermal performance.
What does IP20 imply about the operating environment of HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
IP20 is intended for indoor, cabinet-protected environments and does not guard against moisture or very fine particles. For dusty or wet production areas, mount the drive in a sealed enclosure or add environmental protection to the cabinet.
What should teams document when deploying HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW?
Record firmware versions, parameter baselines, safety wiring diagrams and functional test results for STO and SBC. Thorough documentation simplifies future updates, audits and troubleshooting while maintaining traceability for safety activities.
What commissioning checks validate HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW performance?
Verify encoder feedback, brake actuation timing, thermal behavior under load and network determinism. Capture baseline parameters and test results to support repeatable deployments.
Common Misspellings
HCS011EW0008A03BETECEPNNNNFW
HCS01 1E W0008 A 03 B ET EC EP NN NN FW
hcs01.1e-w0008-a-03-a-cc-ec-da-nn-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW
Internal Product Review
Bosch Rexroth's HCS01.1E-W0008-A-03-B-ET-EC-EP-L4-NN-FW emphasises dual-layer stopping via electronic torque cut and brake control while keeping compact cabinet-friendly dimensions. It is aimed at systems where minimal panel real estate are critical requirements for safe operation.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-EP-NN-NN-FW.