The HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW by Bosch Rexroth Indramat operates at 3 x AC 200–500 V ±10% and delivers 8 A peak current. Part of the HCS IndraDrive Controllers, it features MultiEthernet communication and internal air cooling. The device is IP20 rated with a BASIC control section design paired as Control Section Design 'BASIC'.
It has an IndraDyn Hiperface/EnDat encoder, no second interface, and is in the HCS01 series. The controller uses an infeeding/feeded power supply unit. This HCS Drive Controller delivers reliable performance.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What safety function is included in HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW and how is it applied?
The controller features Safe Torque Off, disabling torque generation on safety events to prevent motion. STO is applied as part of machine safety interlocks, enabling safer maintenance without adding bulky external torque-cut relays.
How does encoder support improve motion control on HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW?
The Hiperface/EnDat encoder interfaces provide deterministic, high-resolution feedback for tight control loops and minimal steady-state error. Such feedback is critical for accurate positioning and smooth trajectory execution in coordinated systems.
How does MultiEthernet assist commissioning for HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW?
MultiEthernet allows direct communication with PLCs and supervision systems, enabling remote parameter uploads and telemetry capture. This reduces physical access requirements and speeds validation for multi-axis setups.
What wiring best practices protect encoder signals for HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW?
Use shielded encoder cables, separate power and signal runs and install robust strain reliefs at connector points. These steps minimize electromagnetic interference and mechanical stresses that can lead to intermittent faults.
How should firmware change be managed for HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW?
Validate any firmware changes in a controlled test environment and perform staged rollouts with rollback capability. Document test outcomes and maintain a single source of truth for approved versions to prevent inconsistencies.
Common Misspellings
HCS011EW0008A03BETECNNS4NNNW
HCS01 1E W0008 A 03 B ET EC NN S4 NN NW
hcs01.1e-w0008-a-03-a-cc-ec-nn-nn-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW
Internal Product Review
HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW blends STO safety and high-resolution encoder support within a blower-cooled, cabinet-friendly form. The device targets retrofits and new builds where electronic torque removal and precision feedback must coexist in minimal cabinet space.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-NN-S4-NN-NW.
Want to 