1-888-551-3082 | 1-919-443-0207 | sales@indramat-usa.com

HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW

HCS IndraDrive Controllers

  Call for Quote
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping

The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW is a high-performance drive controller from the HCS IndraDrive Controllers series, designed to deliver precise motion control in demanding industrial environments. This unit features a MultiEthernet communication interface and an integrated blower for air, internal cooling, ensuring reliable operation under continuous loads. Rated for a mains voltage of 3 x AC 200...500 V ±10%, the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW excels in mid-voltage applications, offering up to 8 A peak current for rapid acceleration and dynamic response.



Built on the robust HCS Compact Converter Series line, this controller implements a Control Section Design Type: BASIC paired with the Control Section Design ‘BASIC’ (B) note, streamlining set-up and reducing commissioning time. The Interface 1 Type supports Encoder IndraDyn Hiperface/EnDat 2.1/2.2, which allows high-resolution feedback and precise position control. The device’s IP20 rating provides solid protection in clean, controlled environments. With a Product Type: HCS Drive Controller and a compact footprint, this model integrates seamlessly into machine tool, packaging, and assembly automation systems.



Additional features include a Power Supply Unit capable of both infeeding and feeded operation, enhancing energy efficiency through regenerative braking. The internal blower cooling method maintains optimal thermal conditions, extending component life and reducing downtime. Its compliance with industry IP20 standards underscores its suitability for cabinet installation in production lines. The drive’s modular design and line designation HCS01 facilitate scalability in multi-axis configurations. By employing the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW, manufacturers can achieve improved throughput, tighter motion accuracy, and reduced energy consumption in automated industrial applications.

Technical Specifications

Communication Interface
MultiEthernet

Pairing Note
Paired with Control Section Design 'BASIC' (B)

Control Section Design Type
BASIC

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
8 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

What makes the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW suitable for multi-axis motion systems?

The drive’s MultiEthernet interface supports high-speed, deterministic communication, enabling seamless synchronization between axes. This ensures precise coordination in applications like robotics, packaging and material handling where motion accuracy is critical.

How does the infeeding/feeded power supply improve performance in the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW?

This topology allows regenerative energy from deceleration phases to be reused across the DC bus. It reduces energy loss, improves efficiency and stabilizes voltage, extending overall system lifespan under continuous loads.

What role does the integrated blower play in the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW?

The blower provides targeted cooling across the power electronics, maintaining thermal balance even during peak current operation. It ensures reliable performance while reducing derating risks in compact cabinet installations.

What encoder interfaces does the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW support?

The controller supports IndraDyn Hiperface/EnDat encoder feedback, providing precise position and velocity data. These protocols allow tight servo tuning, improving repeatability and acceleration accuracy in industrial automation.

How should firmware be managed on the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW?

Firmware updates should follow version-controlled procedures with testing in a staging setup before deployment. Back up all parameters and motion profiles prior to upgrades to ensure rollback safety and consistency across drives.

HCS011EW0008A03BETECNNS5NNAW

HCS01 1E W0008 A 03 B ET EC NN S5 NN AW

hcs01.1e-w0008-a-03-a-cc-ec-nn-s4-nn-fw

HCS1.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW

Internal Product Review

The HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW from Bosch Rexroth Indramat integrates MultiEthernet networking and regenerative infeeding for superior energy efficiency. Its internal blower ensures stable operation under high thermal stress, making it ideal for multi-axis machine environments demanding precision and uptime.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-NN-S5-NN-AW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo