HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW
HCS IndraDrive Controllers
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What telemetry capabilities are exposed by HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW?
MultiEthernet facilitates access to drive health metrics, including temperature trends, current profiles and alarm states, enabling remote diagnostics. With appropriate SCADA integration these metrics feed predictive models that reduce on-site service and improve uptime.
How does HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW manage thermal loads?
An integrated blower directs air over the power stage to maintain thermal margins during continuous duty cycles. Complementing cabinet ventilation and performing periodic blower maintenance are critical for sustaining rated performance and preventing thermal derating.
What cabinet design considerations apply to HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW?
Ensure unobstructed blower intake and exhaust, filter the cabinet air if necessary and maintain spacing for connector access during maintenance. Adequate cabinet airflow planning prevents recirculation and maintains reliable heat dissipation under load.
Which power configuration is supported by HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW and what is the benefit?
The controller supports infeeding/feeded architectures allowing regenerative energy to be recovered into the DC bus when system design permits. This reduces the need for resistive braking and improves overall system energy efficiency during cyclic decelerations.
How can teams reduce commissioning time with HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW?
Preload BASIC parameter templates, verify encoder signals at low speed and confirm network packet timing before ramping to full operation. Document baseline settings and observed performance to accelerate repeatable field deployments.
Common Misspellings
HCS011EW0008A03BETECNNSBNNFW
HCS01 1E W0008 A 03 B ET EC NN SB NN FW
hcs01.1e-w0008-a-03-a-cc-ec-pb-l4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW
Internal Product Review
Bosch Rexroth's HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW emphasizes networked diagnostics through MultiEthernet, exposing telemetry for condition-based maintenance and remote troubleshooting. The blower-cooled, IP20 package is optimized for repeatable integration into panelized OEM systems requiring minimal on-site tuning.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-NN-SB-NN-FW.