HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW
HCS IndraDrive Controllers
The Bosch Rexroth Indramat HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW is a high-performance drive controller within the HCS IndraDrive Controllers series, designed to manage and regulate advanced servo applications. This controller features a MultiEthernet communication interface and provides robust safety functions including STO (Safe Torque Off) for immediate drive disablement. With an integrated blower for air, internal cooling, the HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW ensures optimal thermal management during continuous operation and is specifically developed to pair seamlessly with Control Section Design 'BASIC' (B) for streamlined configuration and deployment.
In-depth technical specifications highlight the controller’s versatility: it operates on a mains voltage of 3 x AC 200...500 V ±10% and delivers a device peak current of 8 A, ideal for dynamic load requirements. Communication is supported through two dedicated interfaces: Encoder IndraDyn Hiperface/EnDat 2.1/2.2 for precise feedback, and PROFIBUS for legacy system integration. The IP20 rating indicates solid protection against solid objects and ease of access in controlled environments. Its line series designation HCS01 and the requirement to order firmware as a separate sub-position underscore the unit’s modular escalability and adaptability to various control architectures.
Additional features emphasize reliability and compatibility in industrial settings. The power supply unit can operate in both infeeding and feeded modes, accommodating diverse power topologies and simplifying system design. Safety is further enhanced by SBC (Safe Brake Control) to ensure controlled deceleration and hold functions under fault conditions. With no additional design features required, the compact converter maintains a clean configuration and minimal maintenance overhead. The HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW drive controller provides exceptional efficiency, operational safety, and ease of integration—delivering precise motion control, reduced downtime, and enhanced productivity across a wide range of demanding industrial applications.
Technical Specifications
Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Other Design Features
None
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
Safety Interface
STO (Safe Torque Off) and SBC (Safe Brake Control)
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
Frequently Asked Questions
What safety features does HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW provide?
This model includes Safe Torque Off to remove torque capability and Safe Brake Control to command mechanical braking for secure axis holding. Their integration ensures overlapping safety measures suitable for high-inertia axes and compliance with stringent safety requirements.
Which fieldbuses are supported on HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW?
The drive supports MultiEthernet for modern networks and PROFIBUS for legacy device interoperability. Use this combined support to integrate with both new and existing control systems without replacing entire field infrastructure.
How does SBC improve stop reliability for HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW?
Safe Brake Control issues a control command to engage mechanical brakes and synchronizes with electronic torque removal to ensure axes are physically restrained. This two-tier stopping strategy is essential when stopping energy cannot be entirely absorbed electronically.
How should the infeeding/feeded power capability be planned for HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW?
Plan DC bus sizing and protective devices to safely accept regenerative energy when the system returns power. Proper bus and protection design allows recovered energy to be reused, improving system energy efficiency across cyclic applications.
What commissioning tests are critical for HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW?
Validate STO and SBC response times, verify encoder signal quality, confirm network packet latency under load and verify thermal performance under representative duty cycles. Record these results for safety dossiers and reproducible system baselines.
Common Misspellings
HCS011EW0008A03BETECPBL4NNFW
HCS01 1E W0008 A 03 B ET EC PB L4 NN FW
hcs01.1e-w0008-a-03-a-cc-ec-pb-s4-nn-fw
HCS1.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW
Internal Product Review
Indramat's HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW is an ideal choice for consistent performance. It simply combines STO and SBC safety with dual fieldbus support to deliver secure, controlled braking and managed network integration. The design is aimed at machine builders needing deterministic Ethernet with legacy PROFIBUS compatibility and certified braking control.
Shipping & Payment Options




Warranty
Repair
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-PB-L4-NN-FW.
Want to 