Communication Interface
MultiEthernet
Pairing Note
Paired with Control Section Design 'BASIC' (B)
Control Section Design Type
BASIC
Cooling Method
Air, internal (through integrated blower)
IP Rating
IP20
Design Version
1
Firmware Order Note
Firmware must be ordered as separate sub position
Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2
Interface 2 Type
PROFIBUS
Safety Interface
Not equipped
Line Series
HCS01
Mains Voltage
3 x AC 200...500 V ±10%
Device Peak Current
8 A
Power Supply Unit
Infeeding / Feeded
Product Type
HCS Drive Controller
HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-AA-FW is simply able to provide the dual-bus flexibility with PROFIBUS legacy integration and compact blower-based thermal management for tight panel footprints. This variant suits systems that demand fieldbus interoperability while retaining high-resolution encoder feedback for precision tasks.
We offer a repair service for the HCS01.1E-W0008-A-03-B-ET-EC-PB-NN-AA-FW.