1-888-551-3082 | 1-919-443-0207 sales@indramat-usa.com

HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW

HCS IndraDrive Controllers

  In-Stock, Ships 3-5 Days
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
Expedited Lead Times on Select Parts
1 Year Warranty Included
Free Ground Shipping
The HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW controller supports 3-phase input, operates at 3 x AC 200-500 V ±10% mains voltage, delivers a peak current of 8 A, and cools via internal blower. Part of the HCS IndraDrive Controllers series by Bosch Rexroth Indramat, it features IP20 protection and operates from -10 to 40 °C.

Technical Specifications

Pairing Note
Paired with Control Section Design 'ECONOMY' (E)

Control Section Design Type
ECONOMY

Cooling Method
Air, internal (through integrated blower)

IP Rating
IP20

Design Version
1

Other Design Features
None

Interface 1 Type
Encoder IndraDyn Hiperface/EnDat 2.1/2.2

Interface 2 Type
Not equipped

Safety Interface
Not equipped

Line Series
HCS01

Mains Voltage
3 x AC 200...500 V ±10%

Device Peak Current
8 A

Power Supply Unit
Infeeding / Feeded

Product Type
HCS Drive Controller

Operating Temperature Range
-10 degrees C to 40 degrees C

Input Phases
3-phase

Mounting Type
Standard

Dimensions (HxWxD)
345 mm x 65 mm x 270 mm

Frequency Range
50 to 60 Hz

What synchronization advantages does HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW bring with SERCOS III?

SERCOS III provides synchronized cycle timing across nodes enabling phase-accurate command execution and minimal jitter. This yields improved trajectory following and reduced mechanical stress in coordinated multi-axis systems.

How should thermal considerations be verified for HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

Conduct continuous-duty thermal profiling under representative load cycles to ensure blower performance remains within expected parameters. Use those profiles to set operational thresholds and maintenance intervals that prevent unexpected derating.

What does IP20 suggest about enclosure selection for HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

It suggests indoor cabinet installation where the environment is controlled and dry, with limited dust exposure. For harsher conditions, specify an IP-rated enclosure or add filtered ventilation to protect internal components.

How does the infeeding/feeded power unit help energy management for HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

It enables sharing or returning regenerative energy to a common DC bus, improving efficiency in stop-start or cyclic applications. Design the DC bus and protections to handle peak regenerated energy safely.

What commissioning logs should be produced for HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW?

Include network topology records, encoder verification logs, thermal run data and firmware/parameter snapshots. These records ensure reproducible installs and speed troubleshooting by showing baseline behaviors.

HCS011EW0008A03ES3ECNNNNNNFW

HCS01 1E W0008 A 03 E S3 EC NN NN NN FW

hcs01.1e-w0008-a-03-a-et-ec-nn-nn-nn-fw

HCS1.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW

Internal Product Review

HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW is one of the most in demand models. This simply offers SERCOS III determinism in a minimal, cabinet-friendly package focused on consistent closed-loop performance. Its blower-based cooling and standard encoder compatibility make it suitable for retrofit projects and standardized OEM installations.

Warranty

1-year-warranty
Indramat USA 1 Year Warranty

Repair

product repair We offer a repair service for the HCS01.1E-W0008-A-03-E-S3-EC-NN-NN-NN-FW.
Indramat Is Trusted By
motion-industries-logo
3m-logo
IBM-logo
GexPro-logo
caterpillar-logo
nasa-logo
ford-logo
vallen-logo